E K J T Pt100 thermocouple patch — LICHENGDA Thermocouples & RTDs

ACCURATE TEMPERATURE SENSING

E K J T Pt100 thermocouple patch

E K J T Pt100 thermocouple patch by LICHENGDA. RTD wiring and insertion geometry, configuration details and made-to-drawing quotation for repeatable process-temperature measurement.

Factory DirectOEM & ODMMade to Drawing

PRODUCT ENGINEERING

RTD wiring and insertion geometry

E K J T Pt100 thermocouple patch: Match the named platinum resistance sensor to the controller’s configured input. Confirm the resistance designation, accuracy class and 2-, 3- or 4-wire arrangement before connecting the probe.

Insertion depth, probe diameter and mounting contact affect response and measurement error. Route the signal cable away from heater power wiring and review cable resistance for the selected connection scheme.

The archived configuration for E K J T Pt100 thermocouple patch lists inner diameter: 6mm,3mm,4mm,5mm,8mm,10mm,12mm,14mm,16mm,20mm; wire length: 0.5m/1m/2m/3m or customzied. Treat these as reference options and reconcile them with the named configuration and installation drawing before quotation.

For E K J T Pt100 thermocouple patch, send the controller input, required measurement range, accuracy, probe drawing and cable or connector details. Ask for the agreed sensor designation and inspection requirements on the quotation.

Application and reference configuration

Repeatable process-temperature measurement. The final suitability of E K J T Pt100 thermocouple patch depends on the assembled equipment and agreed operating conditions.

Archived figures below describe reference options or a product series. Confirm the exact model specification in the quotation.

Namepatch thermocouple
typeK/E/J/T/PT100
Temperature0-600℃ (k),0-400℃ (E),-50-420℃ (PT100)
patch materailcopper
inner diameter6mm,3mm,4mm,5mm,8mm,10mm,12mm,14mm,16mm,20mm
wire length0.5m/1m/2m/3m or customzied
TerminalU type Terminal or plug
patch thickness0.8mm

ARCHIVED PRODUCT INFORMATION

Description

The thermal conductivity is very good, and it can accurately measure the surface temperature of the object. It is to lead the wire directly after putting the temperature sensing element on the protection tube. Users can choose different indexing sleeve sizes and wire materials according to the different

temperature or the size of the measurement space. Generally used in small-scale temperature measurement occasions.

Name

patch thermocouple

type

K/E/J/T/PT100

Temperature

0-600℃ (k),0-400℃ (E),-50-420℃ (PT100)

patch materail

copper

inner diameter

6mm,3mm,4mm,5mm,8mm,10mm,12mm,14mm,16mm,20mm

wire length

0.5m/1m/2m/3m or customzied

Terminal

U type Terminal or plug

patch thickness

0.8mm

E K J T Pt100 thermocouple patch — 贴片热电偶细节 1

Product Advantage

1:High Precision Temperature control probe

2:Accurate measurement accuracy, high sensitivity, wide measurement range -200-600℃

3:Accurate measurement (imported chip)

4:fast response,anti-interference,Good temperature resistance

It seems like you're referring to a "patch thermocouple." A patch thermocouple is a type of temperature sensor that is designed to be attached to a surface to measure its temperature. These are often used in applications where it's important to monitor the temperature of a specific area without intrusive methods.

Model probe range
Pt100 20*7.5*3.6mm -50 to 420℃
Resistance Class A ,Class B Precision ±1℃,±2℃
Wire material Teflon/Silicone rubber (waterproof)/Glass fiber

E K J T Pt100 thermocouple patch — thermocouple patch 1 2

E K J T Pt100 thermocouple patch — Thermal Resistor 3 3

Key Features of Patch Thermocouples:

Surface Mounting: They are typically adhered or attached directly to the surface whose temperature needs to be measured.

Thin and Flexible: Patch thermocouples are usually thin and flexible, allowing them to conform to the shape of the surface.

Quick Response Time: Due to their design, they often have a fast response time to temperature changes.

Variety of Types: They can be made with different types of thermocouple materials (e.g., Type K, Type J, Type T) depending on the temperature range and environment.

Installation Tips:

Surface Preparation: Ensure the surface is clean and smooth for optimal adhesion and accurate readings.

Adhesive Selection: Use an appropriate adhesive that can withstand the temperature range and environmental conditions.

Placement: Position the patch thermocouple in a location that is representative of the area you want to measure.

E K J T Pt100 thermocouple patch — pt100 2 4

E K J T Pt100 thermocouple patch — product detail 5

Types of Thermocouples:

Thermocouples are classified into different types based on the metal combinations used. Each type has a specific temperature range and application suitability:

Type K (Chromel-Alumel): Most common, suitable for a wide range of temperatures (-200°C to 1260°C).

Type J (Iron-Constantan): Used in reducing environments, range from -210°C to 1200°C.

Type T (Copper-Constantan): Ideal for cryogenic applications, range from -250°C to 400°C.

Type E (Chromel-Constantan): High output, suitable for cryogenic and moderate temperatures (-200°C to 900°C).

Type N (Nicrosil-Nisil): Stable at high temperatures, range from -270°C to 1300°C.

Type R/S (Platinum-Rhodium): Used for very high temperatures (up to 1600°C), often in laboratory settings.

Type B (Platinum-Rhodium): Suitable for extremely high temperatures (up to 1800°C).

Related Product Recommendation

E K J T Pt100 thermocouple patch — product detail 6E K J T Pt100 thermocouple patch — product detail 7E K J T Pt100 thermocouple patch — product detail 8

E K J T Pt100 thermocouple patch — product detail 9E K J T Pt100 thermocouple patch — product detail 10E K J T Pt100 thermocouple patch — product detail 11

E K J T Pt100 thermocouple patch — product detail 12E K J T Pt100 thermocouple patch — product detail 13E K J T Pt100 thermocouple patch — product detail 14

E K J T Pt100 thermocouple patch — product detail 15

Company Profile

LICHENGDA company profile and heating element manufacturing facilities

Xiamen Lichengda Precision Manufacturing Co., Ltd. was established in 2 0 1 2 year. It is a

comprehensive company integrating production, sales and technical service. the factory covers an

area of 5000m2, has nearly 100 employees. Applicable quality-system and product-compliance documentation must be confirmed for the quoted product, legal entity and current scope.

Main products : cartridge heater,Tubular heater, Flexible heater, cartridge heater,silicone heater

thermocouple, heating element, and other heating products. The factory introduced advanced

automatic control system and online quality,inspection system to ensure the stability and reliability of product quality

E K J T Pt100 thermocouple patch —  10702 17

1. Qucik Response:Your inquiry will be replied within 24 hours. Response Rate over 90%
2. Smooth Communication: Well-trained and experienced staffs to answer all your inquires.
3. Sincere Service Attitude: Treat Customers As Friends. No Questions are Neglected.
4. OEM Accepted: Free Sample,We can customize your products to meet all your different requests.
5. Small MOQ: Small Amount wholesales are supported to meet your needs as well as large demands.
6. Fast Delivery: We have Reliable Forwarders with long term cooperation and Competitive Price.
You may contact any one of our sales and services team: email to us as inquiry.

Hot Tags: E K J T Pt100 thermocouple patch, China, manufacturers, suppliers, factory, wholesale, customized, cheap, in stock, free sample, thermocouple temperature sensor type s, ceramic k type thermocouple, high temperature k type thermocouple, platinum rhodium s type thermocouple, Stainless Steel PT100 Rtd Thermocouple, rtd thermocouple pt100 temperature sensor

Specifications and availability vary by configuration. Confirm dimensions, materials and electrical or measurement ratings in your quotation.

ENGINEER-REVIEWED QUOTATION

Need this product customized?

Email your drawing →